Polaris

Polaris is a 560 node HPE Apollo 6500 Gen 10+ based system. Each node has a single 2.8 Ghz AMD EPYC Milan 7543P 32 core CPU with 512 GB of DDR4 RAM and four Nvidia A100 GPUs connected via NVLink, a pair of local 1.6TB of SSDs in RAID0 for the users use, and a pair of slingshot network adapters. They are currently slingshot 10, but are scheduled to be upgraded to slingshot 11 in late 2022 or early 2023. There are two nodes per chassis, seven chassis per rack, and 40 racks for a total of 560 nodes. More detailed specifications are as follows:

Polaris Compute Nodes

POLARIS COMPUTE DESCRIPTION PER NODE AGGREGATE
Processor (Note 1) 2.8 GHz 7543P 1 560
Cores/Threads AMD Zen 3 32/64 17,920/35,840
RAM (Note 2) DDR4 512 GiB 280 TiB
GPUS Nvidia A100 4 2240
Local SSD 1.6 TB 2/3.2 TB 1120/1.8PB

Note 1: 256MB shared L3 cache, 512KB L2 cache per core, 32 KB L1 cache per core
Note 2: 8 memory channels rated at 204.8 GiB/s

Polaris A100 GPU Information

DESCRIPTION A100 PCIe A100 HGX (Polaris)
GPU Memory 40 GiB HBM2 160 GiB HBM2
GPU Memory BW 1.6 TB/s 6.4 TB/s
Interconnect PCIe Gen4 64 GB/s NVLink 600 GB/s
FP 64 9.7 TF 38.8 TF
FP64 Tensor Core 19.5 TF 78 TF
FP 32 19.5 TF 78 TF
BF16 Tensor Core 312 TF 1.3 PF
FP16 Tensor Core 312 TF 1.3 PF
INT8 Tensor Core 624 TOPS 2496 TOPS
Max TDP Power 250 W 400 W

Polaris Device Affinity Information

CPU Affinity NUMA Affinity GPU0 GPU1 GPU2 GPU3 mlx5_0 mlx5_1
24-31,56-63 3 GPU0 X NV4 NV4 NV4 SYS SYS
16-23,48-55 2 GPU1 NV4 X NV4 NV4 SYS PHB
8-15,40-47 1 GPU2 NV4 NV4 X NV4 SYS SYS
0-7,32-39 0 GPU3 NV4 NV4 NV4 X PHB SYS
mlx5_0 SYS SYS SYS PHB X SYS
mlx5_1 SYS PHB SYS SYS SYS X

Legend:

X = Self
SYS = Connection traversing PCIe as well as the SMP interconnect between NUMA nodes (e.g., QPI/UPI)
NODE = Connection traversing PCIe as well as the interconnect between PCIe Host Bridges within a NUMA node
PHB = Connection traversing PCIe as well as a PCIe Host Bridge (typically the CPU)
PXB = Connection traversing multiple PCIe bridges (without traversing the PCIe Host Bridge)
PIX = Connection traversing at most a single PCIe bridge
NV# = Connection traversing a bonded set of # NVLinks

Links to detailed Nvidia A100 documentation:
- NVIDIA A100 Tensor Core GPU Architecture
- NVIDIA Ampere Architecture In-Depth

Login nodes

There are four login nodes for editing code, building code, submitting / monitoring jobs, checking usage (sbank), etc.. The various compilers and libraries are present on the logins, so most users should be able to build their code. However, if your build requires the physical presence of the GPU, you will need to build on a compute node.

All users share the same login nodes so please be courteous and respectful of your fellow users. For example, please do not run computationally or IO intensive pre- or post-processing on the logins and keep the parallelism of your builds to a reasonable level.

POLARIS LOGIN DESCRIPTION PER NODE AGGREGATE
Processor (Note 1) 2.0 GHz 7702 2 12
Cores/Threads AMD Zen 3 128/256 768/1536
RAM (Note 2) DDR4 512 GiB 3 TiB
GPUS (Note 3) No GPUS 0 0
Local SSD None 0 0

Note 1: 256MB shared L3 cache, 512KB L2 cache per core, 32 KB L1 cache per core
Note 2: 8 memory channels rated at 204.8 GiB/s per socket
Note 3: If your build requires the physical presence of a GPU you will need to build on a compute node.

Gateway nodes

There are 50 gateway nodes. These nodes are not user accessible, but are used transparently for access to the storage systems. Each node has a single 200 Gbs HDR IB card for access to the storage area network. This gives a theoretical peak bandwidth of 1250 GB/s which is approximately the aggregate bandwidth of the global file systems (1300 GB/s).

Storage

Polaris has access to the ALCF global file systems. Details on storage can be found here.